Comtrol

Industrial Ethernet switches, Multiport serial controllers, Serial to Ethernet and bespoke hardware

t: 01908 929300 >> e:sales@comtrol.co.uk
  • E-mail
  • Google+
  • LinkedIn
  • Twitter

Winner: Best Bespoke Communication Solutions Provider 2018

  • Home
  • About Us
  • Products
    • Industrial Ethernet Switches
      • Satyrn Ethernet Switches
        • Unmanaged Switches
        • Smart Managed Switches
        • Managed Switches
        • X Series Switches
        • Layer 3 Managed Switches
        • Oil & Gas
        • SFP Modules
        • Satyrn Management Software
      • InterGrator Switches
      • Power over Ethernet Switches
    • Omnitron Media Converters
    • IO Link Master Gateways
      • IO-Link Master Gateways – EtherNet/IP
      • IO Link Master Gateways – Modbus
      • IO-Link Master Gateways – PROFINET
    • Transport Solutions
      • Unmanaged Transport Switches
      • Managed Transport Switches
      • Power over Ethernet Transport Switches
      • Wireless Access Points
      • PoE Injectors & Splitters
    • Multiport Serial Cards
      • Rocketport uPCI
      • Rocketport Express
      • Rocketport Infinity
      • Rocketport Plus
      • SMPTE Controllers
      • RocketPort uPCI Interface Boxes
      • RocketPort Express and Infinity Interface Boxes
    • Serial to Ethernet
      • DeviceMaster RTS
      • DeviceMaster Serial Hub
      • DeviceMaster PRO
      • DeviceMaster Industrial Gateways
      • DeviceMaster LT 16
    • Wireless Access Points
    • USB
    • Power Supplies
    • PoE Injectors and splitters
  • Where to buy
  • Support
  • Case Studies
  • Contact Us
  • News
  • Technology Partners
Home / IO-Link / IO Link Master Gateways / IO-Link Master Gateways - EtherNet/IP / IO-Link Master 4-EIP

IO-Link Master 4-EIP

The IO-Link Master features rugged housing with M12 connectors for harsh environments. This industrial IO-Link gateway has a wide operating temperature from 0° to 55°C.

Product Number: 99570-8. Categories: IO-Link Master Gateways - EtherNet/IP, IO Link Master Gateways - Modbus, IO-Link Master Gateways - OPC UA.
  • Description
  • Specifications
  • Accessories
  • Downloads

IO-Linksimultaneous

Comtrol’s IO-Link Master combines the benefits of the IO-Link standard with the EtherNet/IP™ and Modbus TCP protocols. The IO-Link Master effectively shields the PLC programmers from the IO-Link complexities by handling those complexities itself. The result is simplified EtherNet/IP™ and Modbus TCP interfaces,which decreases system development time and installation efforts.

The IO-Link Master features a rugged IP67 slim-line design incorporating two Fast Ethernet ports and four IO-Link ports with M12 connectors. Designed for harsh environments, its machine-mount design uses industrial grade components. The IO-Link Master is easily integrated into a system network, and is compatible with existing and new industrial Ethernet installations.

Hardware
Network Interface 10/100BASE-TX
Enclosure Moulded ABS (Potted)
Ingress Protection Rating IP67
Installation and Grounding Method Machine or Panel Mount
Two-hole M4 or #8 screws
Network Protocols EtherNet/IP™ / Modbus/TCP (slave)
Connectors (M12) 4 – IO Link
2 – Ethernet
2 – Power
Led Indicators Power / Module Status / Network Status / IO-Link / DI and Ethernet Port Link/Activity Status
Dimensions 6.07" x 2.04" x 1.68"
154 x 51.8 x 42.7 mm
Product Weight 0.70 lb / 19.84 kg

IO-Link Interface Specifications
Connector Type Female M12 A-coded 5-pin
Number of ports 4
IO-Link Version Supports V1.0 and V1.1
Connector Pinnout Pin 1 = L+
Pin 2 = DI
Pin 3 = L-
Pin 4 = C/Q
Pin 5 = Not Connected
Configurations per port IO-Link = 1
DI (SIO mode) = 1
DO (SIO mode) = 1
DI (dedicated) = 1
IO-Link Mode Transfer Rates 4.8K (COM1)
38.4K (COM2)
230.4K (COM3)
Baud Rate Recognition Automatic
Output Current on IO-Link Connectors (ports 1-4) C/Q on Pin 4 / Vs on Pins 1/3
200mA (Max) / 500mA (Max)
Short Circuit Protection Yes
Cable Length (max) 20m

Digital Inputs C/Q (SIO Mode Using IO-Link Ports)
Sensor Current Load (max) 200mA
Input Characteristics IEC 61131-2 Type 1 and Type 3 Compliant
Short-Circuit and Overload Protection Yes
Short-Circuit Proof Yes
Input Current Limitation Yes
C/Q Input Threshold Low: 8.0 – 11.5V
High: 10.5 – 13.0V
Cable Length (Max) 30m

Digital Outputs C/Q (SIO Mode Using IO-Link Ports)
Actuator Current Load (Max) 200mA
Short-Circuit and Overload Protection Yes
Short-Circuit Proof Yes
Input Current Limitation Yes
Output Function PNP/NPN
Cable Length (Max) 30m

Ethernet Interface Specifications
Connector Type Female M12 D-Coded 4-pin
Number of Ports 2
Ethernet Specification 10/100BASE-TX
Standards IEEE 802.3: 10BASE-T
IEEE 802.3u: 100BASE-TX
Auto-MDI/MDI-X Yes
Auto-Negotiation Yes
Link Distance 100m
Cable Type Twisted pair (Cat 5 or higher)
IPv4 Addressing Yes

Ethernet/IP Interface Specifications
Supported PLCs Including but not limited to:
Control Logix
Compact Logix
RSLogix
SLC 500
PLC5
MicroLogix
Other Class 1 or Class 3 EtherNet/IP PLCs may be supported
ISDU Read & Writes Up to 40 individual commands in one EtherNet/IP message
ISDU Commands Selectable byte swapping (none / 16-bit / or 32-bit)
Selectable payload sizes (4 to 232 bytes)
ISDU block index
ISDU sub-index
Length of read or write
Data payload
Web Page Configuration Provides the following capabilities:
Port configuration for ISDU Data
Process Data
Transfer Mode
Read/Write
Write PDI to Tag/File
and Read PDO from Tag/File.
EtherNet/IP configuration:
Time to Live (TTL) Network Value
Multicast IP Address Allocation Control
User-Defined Number of Multicast IP Addresses
User-Defined Multicast Starting IP Address
Session Encapsulation Timeout
Diagnostics Yes
Electronic Data Sheets (EDS) Yes
Sample PLC Programs Yes

Modbus TCP Interface
Supported Controllers (Modbus TCP Masters) PLC
HMI
SCADA
OPC Server
Supported Clients Any Modbus TCP Client
Applications on phones/tables
Web Page Configuration Port configuration for ISDU Response Timeout / Process Data and Transfer Mode
Diagnostics Yes

4-EIP Features
Data Storage Automatic or Manual – Upload and/or Download
Device Validation Yes
Data Validation Yes
Powerful Web Interface Provides the following capabilites:
Firmware upgradable
Password protected with Admin / Operator and User accounts
ISDU batch handling
Load IODD files to configure the IO-Link device
IODD Handler parses xml files making them readable and configurable
Log files
Upgradable Firmware Yes (Web page or using PortVision DX)
Remote Parameterization Yes

Electrical Specifications
Input Voltage Range 20-30VDC / 4A (Maximum)
Power Supply In (Us) 4A (Maximum)
Power Consuption (Without Load) 100mA @ 24VDC (Vs)
Power Supply Out (Ua) *Us output available is determined by subtracting the following from the available input current:
IO-Link module power
Actual C/Q current for each IO-Link port (w/out devices) 4A (Maximum*)
Actual Vs current for each IO-Link port
Power Connectors Input (1) – Male M12 A-coded 5 pin
Output (2) – Female M12 A-coded 5 pin

Environmental Specifications
Air Temperature System On 0°C to +55°C*
System Off -40°C to +70°C*
Operating Humidity (non-condensing) 10% to 95%
Storage Humidity (non-condensing) 10% to 95%
Shock/Vibrations EN60068-2-6
EN60068-2-27
Enclosure Rating IP67 (IEC 60529)

Export Information
Packaged Shipping Weight 1.05 lb
455 kg
Package Dimensions (L x W x H) 9.19" x 7.25" x 2.5"
233 x 184 x 63.5mm
UPC Code 7-56727-99570-8
Country of Origin USA
ECCN 5A992
Schedule B Number 8517.62.0050

Regulatory Approvals
Immunity European Standard EN 61000-6-2
IEC/EN 61131-2
IEC 1000-4-2/EN 61000-4-2: Electrostatic Discharge (ESD)
IEC 1000-4-3/EN 61000-4-3: Radiated / Radio-Frequency (RF)
IEC 1000-4-4/EN 61000-4-4: Fast Transient/Burst
IEC 1000-4-5/EN 61000-4-5: Surge
IEC 1000-4-6/EN 61000-4-6: Conducted disturbance
IEC 1000-4-8/EN 61000-4-8: Magnetic field
IEC 1000-4-11/EN 61000-4-11: Dips and Voltage Variations
Emissions European Standard EN 61000-6-4
AS/NZS CISPR-22
FCC Part15 Subpart B
Class A limit
Canadian EMC requirements ICES-003
Safety CSA C22.2 No. 142/UL 508E360395
Other Ingress Protection rating IP67 (IEC 60529)
Environmental & Mechanical testing pre IEC/EN 61131-2
Europeal Standard: 2011/65/EU (RoHS2) Directive.

None listed for this product

IO Link Master 4-EIP UserGuide

IO Link Master Ethernet IP Reference Manual

Initial IO Link Master Setup

IO Link Master Loading IODD Files

IO Link Master Configuring IO-Link Devices Port Table

REQUEST INFORMATION

  • This field is for validation purposes and should be left unchanged.

PRODUCT INFORMATION

Media Converters

Media Converters

RuggedNet Switches

Omniconverter

OmniConverter

Ruggednet

Wireless Access Point

Wireless Access Point

USB

USB

Ethernet Switches

SATYRN

DeviceMaster

DeviceMaster

RocketPort

RocketPort

Transport Switches

Transport Solutions

USB

POE INJECTORS AND SPLITTERS

link to LinkedIn link to Twitter

Comtrol UK A Company registered in England and Wales: 09041682 - VAT Registration Number GB188 0355 87 - Tel: +44 (0)1869 352740 - Email: info@comtrol.co.uk

Copyright © 2021 · Terms Of Use · Privacy Policy · Navitas Websites Aylesbury

Copyright © 2021 · Comtrol on Genesis Framework · WordPress · Log in